Hotline
+86 512-81666096-
185、Characteristics of carbon dioxide spherical tank - doer equipment
Characteristics of carbon dioxide spherical tank Carbon dioxide spherical tank is a spherical tank with uniform stress on the shell. Under the same diameter and working conditions,…
[2021.12.18] -
189、Characteristics of carbon dioxide vacuum tank - duel equipment
Characteristics of carbon dioxide vacuum tank - duel equipment1. Carbon dioxide vacuum tank is a doublelayer structure in the form of vacuum powder insulation. The inner container i…
[2021.12.11] -
188、Process flow of LNG reserve peak shaving Station - doer equipment
Process flow of LNG reserve peak shaving Station - doer equipmentThe process flow of LNG reserve peak shaving station is that after being transported to the station by tank car, the…
[2021.12.04] -
187、Filling system and discharge pipeline of liquid ammonia atmospheric storage tank - DOE…
Filling system and discharge pipeline of liquid ammonia atmospheric storage tankThe liquid in the liquid ammonia atmospheric storage tank is discharged through the liquid discharge …
[2021.12.01] -
186、About safety pipeline of outer tank of liquid ammonia atmospheric storage tank -DOEReq…
For the safety pipeline of the outer tank of liquid ammonia atmospheric storage tank:The top of the outer tank shall be provided with an outer tank emergency relief device (diameter…
[2021.12.01] -
185、Liquid argon atmospheric storage tank - DOER equipment
Liquid argon atmospheric storage tank is an atmospheric bimetallic flat bottom storage tank used to store liquid low-temperature argon. It is generally bimetallic structure. The mid…
[2021.12.01] -
184. Fire (detection) alarm system for large liquid ammonia cryogenic liquid full capacity …
Fire (detection) alarm system for large liquid ammonia cryogenic liquid full capacity tankFor fire (detection) alarm system of large liquid ammonia cryogenic liquid full capacity t…
[2021.09.04] -
183、Large liquid ammonia cryogenic liquid full capacity tank fire protection system - Doer…
Large liquid ammonia cryogenic liquid full capacity tank fire protection system Spray cooling device for fire fighting system of large liquid ammonia low temperature liquid full cap…
[2021.08.28] -
182、Temperature measurement of large liquid ammonia cryogenic liquid full volume tank - Do…
Temperature measurement of large liquid ammonia cryogenic liquid full volume tank Temperature measurement of large liquid ammonia cryogenic liquid full volume tank. Temperature meas…
[2021.08.14] -
181、 Liquid level measurement and control measures of large liquid ammonia cryogenic liqui…
Liquid level measurement and control measures of large liquid ammonia cryogenic liquid full volume tankLiquid level measurement and control measures for large liquid ammonia cryogen…
[2021.07.31] -
180、Pressure measurement and control measures of large liquid ammonia cryogenic liquid ful…
Pressure measurement and control measures of large liquid ammonia cryogenic liquid full capacity tankThe pressure measurement and control measures of large liquid ammonia low temper…
[2021.07.24] -
179、Process flow of large liquid ammonia low temperature full capacity tank system (Part 2…
Process flow of large liquid ammonia low temperature full capacity tank system (Part 2) Discharge of large liquid ammonia low-temperature full volume tank and outlet of storage tank…
[2021.07.17] -
178、Process flow of large liquid ammonia low temperature full volume tank system (I) - Doe…
Process flow of large liquid ammonia low temperature full volume tank system (I)Process overview of large liquid ammonia low-temperature full volume tank system is that the liquid a…
[2021.07.10] -
177、 Selection of main equipment and materials for large liquid ammonia cryogenic liq…
Selection of main equipment and materials for large liquid ammonia cryogenic liquid full capacity tankThe large liquid ammonia cryogenic liquid full capacity tank adopts double-laye…
[2021.07.03] -
176、Technical parameters of large liquid ammonia low temperature full capacity tank - Doer…
Technical parameters of large liquid ammonia low temperature full capacity tankLarge liquid ammonia low-temperature full capacity tank is stored in the inner tank (main container) o…
[2021.06.26] -
184、Technical requirements for anti-corrosion construction of steam water bath reheater - …
Technical requirements for anti-corrosion construction of steam water bath reheater The technical requirements for anti-corrosion construction of steam water bath reheater are as fo…
[2021.11.04] -
183、Technical requirements for derusting construction of steam water bath reheater - Doer …
Technical requirements for derusting construction of steam water bath reheaterThe technical requirements for rust removal of steam water bath reheater are as follows:1. Rust removal…
[2021.10.27] -
182、Technical requirements for steam heated water bath vaporizer - Doer equipment
Technical requirements for steam heated water bath vaporizerSteam heated water bath vaporizer is a hot water circulating heating method, which uses the heat of uninterrupted circula…
[2021.10.16] -
181、Function and overview of water bath carburetor - Doer equipment
Function and overview of water bath carburetorThe water bath vaporizer is an intermediate medium heat exchanger. Its working principle is to use water as the medium, heat water with…
[2021.10.11] -
180、Function and overview of air heated carburetor - Doer equipment
Function and overview of air heated carburetorThe air temperature vaporizer is a wall heat transfer heat exchanger. Its working principle is to use the heat in the surrounding air t…
[2021.09.11]